- ホームページ /
- 産業用品 /
- Test, Measure & Inspect /
- Substance Analysis Instrumentation /
- Dissolved Oxygen Meters & Accessories /
- Oakton Replacement DO Probe Membrane Caps (2)...
Oakton Replacement DO Probe Membrane Caps (2) with Solution (30 mL)
回答者の92%がこの商品を友人に勧めたいと回答
JPY 33608
価格の詳細
配送料と関税を除く ( 配送料と関税は購入手続き時に計算されます )
*すべての商品はアメリカから輸入されます
数量:
Ubuyはお客様のセキュリティとプライバシーの保護に努めています。当社の高度な決済セキュリティシステムは、AES(高度暗号化標準)およびSSL(セキュアソケットレイヤー)プロトコルを使用して送信中の情報を暗号化することで機密性を確保しています。お客様の決済情報は第三者の販売者と共有されることはなく、100%安全に保護されています。
Ensure accurate measurements with Oakton Replacement DO Probe Membrane Caps and solution.
Fast
Shipping
Free
Return*
安全な梱包
100%正規品
PCI DSS 準拠
ISO 27001認証取得
この商品の利点
製品詳細
Product Technical Details
| Package Dimensions | 6.76 x 2.32 x 2.22 inches |
| Item Weight | 0.304 ounces |
| Manufacturer | Oakton |
| Item model number | AO-35640-80 |
どんな人にお勧めですか?
-
Aquarium Enthusiasts
Ideal for aquarists needing to monitor dissolved oxygen levels for fish health and water quality management.
-
Environmental Researchers
Facilitates accurate water testing in field studies, ensuring reliable dissolved oxygen measurements for environmental assessments.
-
Laboratory Technicians
Suitable for lab environments where precise measurements of dissolved oxygen are essential for experiments and analyses.
-
Casual Users
Not ideal for home users without specific needs for dissolved oxygen monitoring or advanced testing capabilities.
製品説明書
お客様の質問と回答
-
質問:
What is the purpose of Oakton Replacement DO Probe Membrane Caps?
回答: Oakton Replacement DO Probe Membrane Caps are designed to protect dissolved oxygen probes from contamination and damage. By creating a sealed environment, these caps ensure that the sensors function correctly and maintain accuracy. Proper maintenance of the probe extends its lifespan and provides reliable results in various applications, such as environmental monitoring, aquaculture, and laboratory experiments. -
質問:
How do I install the Oakton Replacement DO Probe Membrane Caps?
回答: Installing the Oakton Replacement DO Probe Membrane Caps is a straightforward process. First, carefully remove the old caps from the probe. Ensure the probe is clean before gently placing the new membrane caps onto the probe end. Press down firmly to create a secure fit, ensuring no gap exists that could allow air ingress. This installation maintains the integrity of the probe readings, making it suitable for both fieldwork and laboratory assessments. -
質問:
How often should I replace my DO probe membrane caps?
回答: Replacement frequency for DO probe membrane caps depends on usage and environmental factors. Typically, it is advisable to inspect and potentially replace them every few weeks, especially if high levels of contaminants are present in the sample. Frequent replacements ensure optimal probe performance, which is crucial for accurately measuring dissolved oxygen levels in water bodies. Regular maintenance enhances data quality in research and field studies. -
質問:
Can I use the Oakton Replacement DO Probe Membrane Caps with other brands of probes?
回答: While the Oakton Replacement DO Probe Membrane Caps are specifically designed for Oakton probes, compatibility with other brands might vary. It's essential to confirm the dimensions and specifications of your probe to ensure that the membrane caps fit snugly. Proper sealing is critical for maintaining accurate measurements, so using the right components is recommended for optimal performance in applications such as hydroponics or water quality testing. -
質問:
What comes in the package of Oakton Replacement DO Probe Membrane Caps?
回答: The package of Oakton Replacement DO Probe Membrane Caps typically includes two membrane caps and a 30 mL solution that helps in maintaining the probe’s performance. This solution ensures the membrane remains hydrated, which is vital for accurate dissolved oxygen readings. Keeping the membrane moist enhances the sensitivity and responsiveness of the probe, making it capable of providing precise data in various testing situations. -
質問:
Are the Oakton Replacement DO Probe Membrane Caps reusable?
回答: No, the Oakton Replacement DO Probe Membrane Caps are not designed for reuse. Each cap is single-use to ensure that the measurements remain accurate and free from contamination. Reusing caps can lead to degraded performance and faulty readings. Single-use caps are essential for maintaining the integrity of experiments or monitoring tasks in fields like aquaculture, giving you peace of mind about the quality of your data. -
質問:
What types of applications require the use of DO probe membrane caps?
回答: DO probe membrane caps are essential in various applications, including environmental monitoring, aquaculture, and laboratory research. In environmental monitoring, they are used to measure oxygen levels in lakes and rivers, while in aquaculture, they help in assessing oxygen levels in fish farms. Accurate readings are vital in these settings to ensure the health and sustainability of aquatic life, making these caps crucial for reliable measurements. -
質問:
Is there a specific storage method for the solution included with the caps?
回答: Yes, it is important to follow proper storage guidelines for the solution included with the Oakton Replacement DO Probe Membrane Caps. Store the solution in a cool, dry place away from direct sunlight and extreme temperatures. Keeping it sealed when not in use prevents contamination and helps maintain its effectiveness for prolonging probe performance. Proper storage ensures that your solution remains active for the duration of your usage. -
質問:
What should I do if I notice inaccuracies in my DO probe readings?
回答: If you notice inaccuracies in your DO probe readings, first check the membrane caps for any signs of wear or damage. If they appear compromised, replace them immediately with Oakton Replacement DO Probe Membrane Caps. Additionally, ensure that the probe is clean and calibrated correctly. Environmental factors affecting the water sample can also lead to skewed readings, so validating the probe's condition regularly is crucial for reliable measurement. -
質問:
Where can I buy Oakton Replacement DO Probe Membrane Caps 2 with Solution 30 mL?
回答: You can buy Oakton Replacement DO Probe Membrane Caps 2 with Solution 30 mL from Ubuy in Japan. Ubuy offers a convenient platform for sourcing quality laboratory equipment and supplies, ensuring that you receive genuine products. This makes it easy to maintain the functionality of your dissolved oxygen probes, enabling accurate and reliable water quality testing.
Oakton Dissolved Oxygen Meters & Accessories AO-35640-80 Editorial Review
お客様のレビュー&評価
-
5 星
100%
-
4 星
0%
-
3 星
0%
-
2 星
0%
-
1 星
0%
この商品のレビュー
お考えをお聞かせください
長所
- High-quality membrane caps
- Easy to install and use
- Compatible with Oakton probes
- Includes generous solution amount
短所
- Limited color options available.
プラットフォームの信頼性とお客様の安心
“Great products and very good service: very easy and very fast international delivery.”
“Wonderful online shopping experience, smooth transaction from the start. Payment method works conveniently and delivery is unexpectedly fast and reliable. You go the extra mile for service. What makes this even more amazing, you deliver to Namibia. I will remain a happy Ubuy customer and will increase my purchases for sure! Thank you!”
“Very easy to find the products what you need, and so fast delivery, that’s why I highly recommended to others costumers to used ubuy.”
“I received exactly what I ordered I was skeptical about your site because that was my first time to order. But the order came timely and neatly packaged. I was not disappointed. Thank you.”
“Easy to find and order what you want on the website. Delivery is quick to the UK”
価格推移
重要な情報
- 注意:国際運送の商品に関して、製造会社保障は無効になる可能性、アフターサービスは受けれない可能性、取説や安全情報は発送先の言語になっていない可能性ある。商品とその付属品は配送先の国の規格、仕様、ラベル表示法などに適応していない可能性があります。また、配送先の国の電力企画に適応しいない(アダプタや変換器を必要とする)可能性があります。ご注文の商品は配送先の国に輸入することは合法なのかを確認するのは購入者の責任になります。Ubuyからご購入の際、受け取り者は正式な輸入者となり、配送先の全ての法律やルールに遵守する必要があります。
- Ubuyはグローバル検索エンジンのためリストにある全ての商品が購入できないことがあります。商品は輸出規制、貿易規制があります。
JPY 33608
今すぐ注文すると 頃に届きます 水曜日, 9月 30
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
数量:
PCI DSS準拠・ISO 27001:2022認証取得。すべてのご注文に暗号化決済と充実したバイヤープロテクションが適用されます。
特徴と利点
- Includes 2 replacement membrane caps for DO probes.
- Comes with a 30 mL solution for effective use.
- Designed specifically for models 35640-50 through 35640-56.
- Easy to install for convenient use.
- Made in the USA for quality assurance.
- Essential for maintaining accurate probe functionality.
Ubuyの安心保証
100%正規品、PCI DSS準拠の決済セキュリティ、ISO 27001認証のデータ保護、最速の国際配送、無料返品※、安全な梱包をすべてのご注文でお届けします。