- ホームページ /
- 産業用品 /
- Test, Measure & Inspect /
- Substance Analysis Instrumentation /
- Electrodes /
- Total Ionic Strength Adjustment Buffer (TISAB...
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
JPY 30048
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from アメリカ
QTY:
Ubuyはお客様のセキュリティとプライバシーの保護に努めています。当社の高度な決済セキュリティシステムは、AES(高度暗号化標準)およびSSL(セキュアソケットレイヤー)プロトコルを使用して送信中の情報を暗号化することで機密性を確保しています。お客様の決済情報は第三者の販売者と共有されることはなく、100%安全に保護されています。
Ready-to-use solutions provide savings in raw materials, labor and waste disposal.
Fast
Shipping
Free
Return*
安全な梱包
100%本物
PCI DSS 準拠
ISO 27001 保証
この商品の利点
製品詳細
| Item Weight | 1.5 lbs (680 grams) |
どんな人にお勧めですか?
-
Laboratory Technicians
Essential for technicians conducting fluoride analysis using ion selective electrodes in various laboratory environments.
-
Environmental Scientists
Ideal for scientists assessing water quality and fluoride concentrations in environmental samples and field studies.
-
Academic Researchers
Beneficial for researchers in academia performing experiments related to fluoride chemistry and ion analysis.
-
Home Users
Not suitable for casual users without specialized knowledge or equipment for fluoride testing at home.
-
Non-technical Professionals
May be overwhelming for professionals lacking technical expertise in ion selective electrode usage and chemical analysis.
-
Small Scale Applications
Not recommended for small, infrequent tasks where comprehensive fluoride analysis techniques are unnecessary.
製品説明書
Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes
顧客の質問と回答
-
質問:
What is TISAB II and its role in fluoride analysis?
答え: Total Ionic Strength Adjustment Buffer (TISAB II) is a specialized buffer solution used to stabilize ionic strength during fluoride analysis with ion-selective electrodes. It ensures accurate readings by maintaining consistent ionic conditions, which is crucial for the reliability of fluoride measurements in various samples, such as drinking water or biological fluids. The presence of CDTA in TISAB II enhances its effectiveness by binding with interfering metal ions, providing clearer and more precise analysis outcomes. -
質問:
How do I use TISAB II with ion-selective electrodes?
答え: To utilize TISAB II effectively, first prepare your sample by diluting it as necessary, then add TISAB II in a defined ratio. This mixture can be directly introduced to an ion-selective electrode designed for fluoride detection. The buffer's function is to control ionic strength and minimize interferences, which is vital for obtaining precise and reproducible fluoride concentration readings in environmental samples or clinical assessments. -
質問:
What are the main components of TISAB II?
答え: TISAB II primarily consists of a blend of buffers that stabilize pH and ionic strength, along with CDTA, which is a chelating agent that binds metallic ions. This combination enhances the accuracy of fluoride detection by minimizing the effect of contaminants and competing ions in the sample. By ensuring that the analytical conditions are consistent, TISAB II plays a key role in various applications, from water quality testing to food safety analysis. -
質問:
Why is CDTA included in TISAB II?
答え: CDTA, or trans-1,2-diaminocyclohexane-N,N,N',N'-tetraacetic acid, is included in TISAB II to enhance the buffer’s ability to remove potential interference from metal ions. These ions can adversely affect the performance of the ion-selective electrode used for fluoride analysis. By binding with these interfering species, CDTA helps in obtaining more reliable and accurate fluoride concentration measurements, which is particularly important in regulatory compliance and research scenarios. -
質問:
Can TISAB II be used for other ions aside from fluoride?
答え: While TISAB II is primarily designed for fluoride analysis, its buffered system can be adapted for other ions that require significant ionic strength adjustments. However, its specificity and the effectiveness of CDTA may not be the same for every ion type. Researchers often use TISAB II in conjunction with the appropriate ion-selective electrodes tailored for the specific analyte being tested, ensuring reliable readings in various analytical contexts. -
質問:
What is the recommended storage condition for TISAB II?
答え: TISAB II should be stored in a cool, dark place, ideally at room temperature, to maintain its integrity. It is important to keep the buffer away from direct sunlight and extreme temperatures, which can degrade the solution over time. Proper storage ensures that the buffer maintains its optimal pH and ionic strength, crucial for accurate fluoride analysis when utilized in testing laboratories or field applications. -
質問:
How does TISAB II affect the pH of a sample?
答え: TISAB II is formulated to maintain a neutral pH, typically around 5.0 to 5.5, which is ideal for fluoride measurements. Adding TISAB II to a sample helps to regulate its pH, crucial for ensuring that fluoride exists in a stable, measurable state. This controlled pH environment is essential in achieving accurate calibrations and results, especially in water quality assessments or food analysis, where pH can fluctuate significantly. -
質問:
Is TISAB II compatible with all ion-selective electrodes?
答え: TISAB II is primarily used with ion-selective electrodes designed specifically for fluoride detection. However, compatibility can vary based on the electrode’s chemistry and design. It is advisable to consult the manufacturer’s guidelines for specific electrodes to ensure they are suitable for use with TISAB II. This compatibility check is particularly essential to avoid erroneous readings in scenarios like environmental monitoring or product testing. -
質問:
What types of samples can be analyzed using TISAB II?
答え: TISAB II can be used to analyze a broad range of samples, including drinking water, wastewater, food products, and biological samples such as saliva or serum. Each sample type may require specific preparation steps, such as dilution prior to adding TISAB II, to ensure that fluoride concentration can be accurately quantified. This versatility makes TISAB II invaluable in laboratories working on environmental, health, or safety assessments. -
質問:
Where can I buy Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes in Japan?
答え: You can purchase Total Ionic Strength Adjustment Buffer (TISAB II), with CDTA for Fluoride Analysis Using Ion Selective Electrodes at Ubuy. Ubuy offers a wide selection of chemical products and laboratory supplies, making it a reliable source for your analytical needs in Japan. The platform provides easy access to institution-quality reagents perfect for both professional and academic use.
RiccaChemical Electrodes Editorial Review
お客様のレビュー&評価
-
5 星
100%
-
4 星
0%
-
3 星
0%
-
2 星
0%
-
1 星
0%
この商品のレビュー
お考えをお聞かせください
Product Price History
重要な情報
- 注意:国際運送の商品に関して、製造会社保障は無効になる可能性、アフターサービスは受けれない可能性、取説や安全情報は発送先の言語になっていない可能性ある。商品とその付属品は配送先の国の規格、仕様、ラベル表示法などに適応していない可能性があります。また、配送先の国の電力企画に適応しいない(アダプタや変換器を必要とする)可能性があります。ご注文の商品は配送先の国に輸入することは合法なのかを確認するのは購入者の責任になります。Ubuyからご購入の際、受け取り者は正式な輸入者となり、配送先の全ての法律やルールに遵守する必要があります。
- Ubuyはグローバル検索エンジンのためリストにある全ての商品が購入できないことがあります。商品は輸出規制、貿易規制があります。
JPY 30048
今すぐ注文すると 頃に届きます 土曜日, 7月 18
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuyはお客様のセキュリティとプライバシーの保護に努めています。当社の高度な決済セキュリティシステムは、AES(高度暗号化標準)およびSSL(セキュアソケットレイヤー)プロトコルを使用して送信中の情報を暗号化することで機密性を確保しています。お客様の決済情報は第三者の販売者と共有されることはなく、100%安全に保護されています。
特徴と利点
- Manufactured with ACS Reagent grade raw materials.
- Intended for precise Fluoride Analysis using Ion Selective Electrodes.
- Lot numbered and expiration dated for quality assurance.
- Tight specifications ensure the most accurate results.
- Minimal lot-to-lot variation enhances reproducibility.
- Certified traceable to NIST for regulatory compliance.