Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Conductivity values are accurate to within ±1% and are referenced to 25°C
Fast
Shipping
Free
Return*
Secure Packaging
100% Original Products
PCI DSS Compliance
ISO 27001 Certified
What Stands Out
Product Details
| Item Weight | 1 lbs (450 grams) |
Who Should Buy?
-
Laboratory Technicians
Ideal for technicians needing accurate conductivity measurements for various laboratory tests and experiments.
-
Water Quality Analysts
Helpful for analysts assessing water quality in environmental studies or municipal water safety evaluations.
-
Calibration Professionals
Perfect for professionals who need a reliable standard for calibrating conductivity meters with precision.
-
Casual Users
Not suitable for casual users who require basic conductivity measurements without needing high precision.
-
Budget-Conscious Buyers
May not meet the needs of buyers looking for a low-cost solution, as it is a premium product.
-
Non-Scientific Uses
Inappropriate for users needing conductivity measurement for non-technical purposes or mundane tasks.
Product Description
Myron L Conductivity Calibration Standard, 30,100 S
About This Item
Introducing the Myron L 30K QCP NIST Conductivity Calibration Standard – the ultimate solution for accurate conductivity readings. With a precision of ±1%, this calibration standard ensures that your conductivity values are always precise and reliable. The values are referenced to 25°C, guaranteeing accurate measurements in any environment.
What sets this calibration standard apart is its user-friendly features. It comes with NaCl and 442 conversions included, making it incredibly convenient and easy to use. No need for additional calculations or adjustments - simply select the conversion you need and get accurate readings instantly. Rest assured, the Myron L 30K QCP NIST is built to last.
It comes with a 1-year warranty, giving you peace of mind and assurance of its quality and longevity. Whether you're in a laboratory setting, industrial facility, or any other industry that requires precise conductivity measurements, trust the Myron L 30K QCP NIST to deliver unparalleled accuracy and reliability. Shop now and experience the difference of using a trusted and renowned brand in conductivity calibration – Myron L.
Customer Questions & Answers
-
Question:
What is the Myron L 30K QCP NIST conductivity calibration standard used for?
Answer: The Myron L 30K QCP NIST conductivity calibration standard is essential for accurately calibrating conductivity meters. It provides reference points at 30 and 100 µS, ensuring your measurements are reliable and consistent. This is particularly important in industries like water quality testing, aquaculture, and environmental monitoring, where precise conductivity readings are critical for regulatory compliance and process control. -
Question:
How do I use the Myron L 30K QCP for calibration purposes?
Answer: Using the Myron L 30K QCP standard for calibration is straightforward. Simply immerse the probe of your conductivity meter in the calibration standard solution and adjust your meter until it matches the standard’s known conductivity value. Following this procedure allows you to maintain the accuracy of your measurements, enhancing the performance of your equipment in laboratories or field testing scenarios. -
Question:
Is the Myron L 30K QCP NIST conductivity calibration standard compatible with all conductivity meters?
Answer: The Myron L 30K QCP NIST calibration standard is compatible with most conductivity meters that can accurately measure mentioned ranges. It’s important to check the specifications of your meter to ensure they are designed for the specific conductivity levels of 30 and 100 µS. Utilizing appropriate standards is crucial for maintaining the reliability of tests in research labs, wastewater treatment, and various industrial applications. -
Question:
Why is the calibration standard NIST certified?
Answer: NIST certification assures that the Myron L 30K QCP calibration standard is traceable to national measurement standards, ensuring high accuracy and reliability. This compliance is crucial for industries reliant on precise measurements, such as pharmaceuticals and manufacturing, where exact conductivity levels can affect product quality and safety. -
Question:
Can I use the Myron L 30K QCP with different solutions?
Answer: While the Myron L 30K QCP is specifically designed for 30 and 100 µS conductivity values, using it with solutions outside of these parameters is not recommended. Different solutions may not provide reliable readings. For accurate results, it’s best to utilize the standard as intended, particularly in settings like environmental testing, where accurate comparisons against recognized standards are essential. -
Question:
How frequently should I calibrate my conductivity meter with the Myron L 30K QCP?
Answer: Calibration frequency for your conductivity meter using the Myron L 30K QCP standard depends on the application's precision requirements. A common guideline suggests calibrating daily or before critical measurements in sensitive applications. Regular calibration helps ensure accuracy in water quality testing, aquaculture monitoring, and other applications where conductivity changes can greatly impact results. -
Question:
What should I store the calibration standard in?
Answer: Store the Myron L 30K QCP calibration standard in its original container to prevent contamination and evaporation. Ensuring that the container is sealed and kept at a stable temperature will maintain the standard's integrity. Proper storage is vital in laboratory settings where accurate reproducibility of results is required for quality assessments and compliance monitoring. -
Question:
Does the Myron L 30K QCP calibrate only conductivity meters?
Answer: Primarily, the Myron L 30K QCP standard is designed for calibrating conductivity meters. However, it can also be beneficial for devices measuring total dissolved solids (TDS) since there's a direct relationship between conductivity and TDS. This versatility is particularly useful in fields like hydroponics and aquaculture, where understanding TDS alongside conductivity can lead to better management of water quality. -
Question:
What is the significance of using a NIST-certified standard?
Answer: Using a NIST-certified standard like the Myron L 30K QCP ensures that your measurements are traceable and reliable. This certification increases confidence in your data, which is crucial for compliance with industry regulations, maintaining safety protocols, and making informed decisions in research, environmental monitoring, and manufacturing. -
Question:
Where can I buy the Myron L 30K QCP NIST conductivity calibration standard in Japan?
Answer: You can purchase the Myron L 30K QCP NIST conductivity calibration standard from Ubuy in Japan. Ubuy offers a variety of calibration solutions to meet your needs, ensuring access to quality products for all your conductivity testing requirements.
Myron L Electrochemistry Accessories Editorial Review
Customer Reviews & Ratings
-
5 Star
100%
-
4 Star
0%
-
3 Star
0%
-
2 Star
0%
-
1 Star
0%
Review this product
Share your thoughts with other customers
Pros
- Highly accurate calibration standard
- Wide conductivity range: 30-100 µS
- NIST-traceable certification
- Easy to use for various devices
- Durable and stable solution
Cons
- Limited to specific conductivity ranges
Product Price History
Important information
- Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
- Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.
JPY 15861
Order now and get it around Friday, July 03
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy works hard to protect your security and privacy. Our advanced payment security system ensures confidentiality by encrypting your information during transmission using AES (Advanced Encryption Standards) and SSL (Secure Socket Layer) protocols. Your payment details are 100% secure as we do not share your payment details with third party sellers.
Features & Benefits
- Accurate to within ±1%
- Referenced to 25°C
- NaCl and 442 conversions included
- 1 year warranty
- 30,100 µS conductivity calibration standard
- 30000 ppm442 conductivity-to-TDS calibration values
- 30.1 mS conductivity value
- 3.3E-05 Mom resistivity value
- 946 mL Volume